Workstation for Pipettes Calibration

RADWAG · Pipettes Calibration · Pipette Calibration Solution · Other

Workstation for Pipettes Calibration

Product code: WL-101-0181

Request a quotation

Overview

SDKP Workstation for Pipettes Calibration

In order to ensure measurement traceability, meet all the requirements resulting from supervision over measuring equipment and to facilitate the process of pipettes calibration RADWAG recommends effective and ergonomic solution for calibrating automatic pipettes conducted by a user - complete workstation for pipettes calibration.

Application:
Calibration of automatic pipettes:

  • with fixed volume
  • with adjustable volume.

Unit contents:

  • table for calibration
  • anti-vibration table
  • probe for temperature, humidity and pressure measurement
  • probe for water temperature measurement
  • sink for used water
  • armrests
  • LCD monitor
  • PC with pre-installed software PIPETTES RADWAG
  • power supply
  • keyboard and mouse
  • container for used water

Adapters for pipettes calibration
Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table presents the minimum reguirements in accordance with ISO 8655 standard. It also enables to select suitable adapter for pipette calibration and respective balance version.


Selected volume1
of apparatus under test

V

 

Resolution
 mg
Repeatability
and linearity mg
Recommended balance
1 µl ≤ V ≤ 10 µl 0,001 0,002
MYA 21.5Y PLUS
MYA 21.5Y
XA 6/21.5Y.M.A PLUS
XA 6/21.5Y.M.A
XA 6/21.5Y.M
 
10 µl ≤ V ≤ 100 µl 0,01 0,02
XA 82/220.5Y.A PLUS
XA 82/220.5Y.A
XA 82/220.5Y
XA 120/250.5Y.A PLUS
XA 120/250.5Y.A
XA 120/250.5Y
100 µl ≤ V ≤ 1000 µl 0,1 0,2
1 ml < V ≤ 10 ml 0,1 0,2
Adapter for pipette calibration  MY 11 XA 11 XA 17 XA 100 XA 17 XA 100
Maximum vessel capacity  11 ml 11 ml 17 ml 100 ml 17 ml 100 ml
Weighing vessel mass  ~ 10 g ~ 10 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g

1 For practical purposes, the nominal volume may be used to choose the balance [Reference: ISO8655-6:2002, pg. 2].
If the standard uncertainty of measurement of the balance is known (e.g. from the balance calibration certificate), it may be used instead of the repeatability and linearity. The standard uncertainty of measurement shall not be more than two to three times the resolution [Reference: ISO8655-6:2002, pg. 2].
 

Datasheet

Delivery componentstable for calibration, anti-vibration table, probe for temperature, humidity and pressure measurement, probe for water temperature measurement, sink for used water, armrests, LCD monitor, PC with pre-installed software PIPETTES RADWAG, power supply, keyboard and mouse, container for used water
Packaging dimensions W x D x H820×1160×890 mm
Length1100 mm
Width750 mm
Height1100 mm
Number of workstations1